| Koehler Viscometer Accessories |
 |
Viscometer Holders |
- For use with glass capillary viscometers
- Select round plastic holders or self-aligning rectangular metal holders to match
ports in viscometer bath
|
| Ordering Information | Round Holder | Rect. Holder |
| Viscometer Type | Catalog No. | Catalog No. |
| Cannon-Fenske Routine | K23381 | K23310 |
| Cannon-Fenske Opaque |
| Cannon-Manning Semi-Micro |
| Ubbelohde | K23382 | K23320 |
| Cannon-Ubbelohde | K23384 | K23361 |
| Cannon-Ubbelohde Semi-Micro |
| Zeitfuchs Cross-Arm | K23383 | K23362 |
| BS/IP/RF U-Tube | K23387 | K23330 |
| Cannon-Manning Vacuum | K23388 | K23360 |
| Modified Koppers | K23363 | K23364 |
| Universal Tube Holders |
- Can be used interchangeably with Cannon-Fenske, Cannon-Manning, Zeitfuchs,
Cross-Arm, and Ubbelohde type capillary viscometers.
- Choice of round (2" dia.) plastic holders or rectangular metal holders.
|
| Catalog No. |
Ordering Information |
| K23351 | Universal Viscometer Holder, Round |
| K23350 | Universal Viscometer Holder, Rectangular |
| Bath Oil |
- White mineral oil for routine applications
- Silicone fluid for high temperature applications
|
|
White Mineral Oil
|
- Highly refined white technical oil for use in constant temperature
baths. Contains an oxidation inhibitor to limit clouding at higher temperatures.
- Suitable for use at temperatures of up to 275O°F (1350°C).
- Nominal Viscosity = 14.2-17.0 cSt @40°C
- Minimum Flash Point = 355°F(179°C)
- Specific Gravity @ 250°C = 0.839-0.855
- Catalog No. 355-001-001
- Shipped in 1 gal. (3.785 1) containers
|
| Silicone Fluid |
- Clear heat transfer fluid with high oxidation resistance and low
volatility, Recommended for constant temperature bath applications
above 275O°F (1350°C).
- Suitable for use at temperatures of up to 275°F (135°C).
- Nominal Viscosity = 100 cSt @ 25°C
- Minimum Flash Point = 620°F(327°C)
- Specific Gravity @ 25°C = 0.964
- Catalog No. 355-001-002
- Shipped in 1 gal. (3.785 1) containers
|
| Vacuum Regulator |
For "ASTM D2171 Viscosity of Asphalts by Vacuum Capillary Viscometers"
Built-in vacuum pressure pump
|
|
Precisely controls vacuum or pressure from 0 to 500 mm mercury below or above
atmospheric pressure. Recommended for use with Cannon-Manning, Asphalt
Institute or Modified Koppers vacuum viscometers. Includes mercury-in-glass
manometer with adjustable scale, solenoid valve and surge tank, and vacuum
pressure pump. Housed in an enameled steel cabinet,10" I x 12" w x 27" h
(25.4 x 30.5 x 68.6 cm). Supplied without mercury - requires 2.5 lb.
|
| Catalg No. | Ordering Information |
| K23460 | Vacuum Regulator, 115V 50/60 Hz |
| K23461 | Vacuum Regulator, 220-240V 50/60 Hz |
This site was last updated on June 19, 2006.
|